Detectors and Accessories | Magnetic Contacts Recessed Mount | 259
EMK 46 S Z Flush-Mount
Magnetic Contact
Features
▶
Conventional flush-mount magnetic contact
▶
VdS class C
▶
Tamper switch
▶
Head-on flush mounting
▶
Conventional perimeter protection
Conventional magnet contacts are used for tear-off
surveillance of windows and doors.
Certifications and Approvals
Region Certification
Europe CE EMK 46 S Z
Germany VdS G 196041, C EMK 46 S
Installation/Configuration Notes
Installation notes
•
Installation is head-on in door or window frames.
•
Installation can be completed with or without a plastic
sleeve. If no plastic sleeve is used, the components
should be fixed in the bores.
•
Installation in ferromagnetic materials is not
permissible.
•
The supply lines need to be measured electrically
before connection.
1 Contact
2 Magnet
3 Installation offset
Distances diagram
1 Extraction
2 Proximity switch part
Note: If the attached magnets are touching each other, there will
be no tamper zone!
Parts Included
Type Qty. Component
EMK 46 S Z 1 Built-in magnetic contact
incl. flange and sleeves
Technical Specifications
Type of installation Flush, head-on
Permissible operating voltage Max. 40 V_
Contact type 1-pin (normally) open contact
Permissible contact load 6 VA
Max. 100 V_
Max. 500 mA
Protection category IP 67
VdS environmental class IV
Permissible
ambient temperature
-25 °C to +70 °C
Housing
•
Material
ABS
•
Color
White
www.boschsecurity.com Bosch Security Systems B.V.
5