416 | Conettix - Information Transport Solutions | Conettix IP
Certifications and Approvals
Region Certification
Europe CE 89/336/EEC, EN55022: 1997 +A2:
2002, EN50130-4: 1995 +A1: 1998 +A2:
2003, EN60950: 2000, EN61000-3-2:
2001, EN61000-3-3A1: 2001,
EN61000-4-2: 1995 +A1: 1998 +A2:
2001, EN61000-4-3: 1996 +A1: 1998
+A2: 2000, EN61000-4-4: 1995 +A1:
2001 +A2: 2001, EN61000-4-5: 1995
+A1: 2001, EN61000-4-6: 1996 +A1:
2000, EN61000-4-11: 1994 +A1: 2001
USA UL AMCX: Central Station Alarm Units
(UL1610, UL1635), AMCX7: Central
Station Alarm Units Certified for Canada
(cULus), APAW: Police Station Alarm Units
(UL365, UL464), APAW7: Police Station
Alarm Units Certified for Canada (cULus),
APOU: Proprietary Alarm Units (UL1076),
APOU7: Proprietary Alarm Units Certified
for Canada (cULus), NBSX7: Household
Burglar Alarm System Units Certified for
Canada (cULus), UTOU7: Control Units and
Accessories - Household System Type
Certified for Canada (cULus)
UL864, 9th edition
FM
CSFM 7167-1615: 100, 7165-1615: 119,
7170-1615: 145, and 7300-1615:
180 July 2008
NYC-MEA 12-92-E, Vol. XIII and 12-92-E, Vol. 15
France AFNOR NF, A2P Type 2 (122000076-05)
Note FM Approval applies when the DX4020 is used
with the Conettix D6600 Communications
Receiver/Gateway.
Installation/Configuration Notes
Compatibility information
Applications
RPS: Supported on all compatible control panels.
PC9000: Supported on the following control panels:
D9412G, D7412G, D7212G, D9112, D7412,
and D7212.
Building Integration
System (BIS) Security
Engine:
Supported on the following SDI bus control panels
(version 6.3 and higher): D9412GV2,
D7412GV2, D7212GV2, D9412G, D7412G, and
D7212G.
CMS 7000: Supported on DS7400Xi‑CHI Control Panels (op-
tion bus) set at Mode 18 (version 4.10 or higher).
SDI Bus Control Panels (version 6.0 or higher)
•
D9412GV2, D7412GV2, and D7212GV2
•
D9412G, D7412G, and D7212G
•
D9412, D7412, and D7212
•
D9112
Option Bus Control Panels
•
DS7400Xi (version 4.10 or higher)
•
CC7420‑A
•
DS7220 and DS7240 (version 2.10 or higher)
•
FPD‑7024
Connection Considerations
The DX4020 uses a standard Category 3 or Category 5 cable
with an RJ‑45 plug to connect to the network, a two-wire
connection from the control panel bus, and two wires that
connect to the control panel or a power supply for DC
power. For 10BASE‑T, use Category 3 or better. For
100BASE‑T, use Category 5 or better.
Mounting Considerations
The DX4020 mounts to the standard three-hole patterns in
supported control panel enclosures. With the D137
mounting bracket, the DX4020 mounts to other enclosures.
Parts Included
Quant. Component
1 Ethernet network interface module
1 Cable assembly, quick connect
1 Hardware pack
1 Literature - Installation Guide
Technical Specifications
Environmental Considerations
Dimensions: 7.6 cm x 12.7 cm (3 in. x 5 in.)
Operating Temperature: 0°C to +50°C (+32°F to +122°F)
Relative Humidity: 5% to 85% at 30°C (86°F) non‑condensing
Power Requirements
Current: 10Base‑T: 110 mA maximum
100Base‑T: 135 mA maximum
Voltage (Operating): 12 VDC nominal
Ordering Information
Conettix DX4020 Ethernet Network
Interface Module
Creates two‑way communications over Ether-
net networks for compatible control panels.
DX4020
Accessories
AE1 Standard Enclosure (Gray)
Standard gray enclosure with keyed lock.
Measures 35.6 cm x 31.8 cm x 7.6 cm (14 in.
x 12.5 in. x 3 in.).
AE1
Bosch Security Systems B.V. www.boschsecurity.com
7