15 Alarm Menu
The Alarm menu provides access to edit the alarm options.
15.1 Releasing an Alarm
There are two modes of operation. Time out releases the alarm after the dwell time. However,
time out may also be released by pressing OFF + 6 + 5 + ENTER. Momentary can only be
released with the following sequence: press OFF + 6 + 5 + ENTER.
MAIN MENU ALARM MENU
PRESET INPUT: NO
TOUR OPTION: MOMENTARY
AUTO PAN PRESET: 05
SECTOR DWELL TIME
ALARM SAVE AND EXIT
CAMERA SETUP EXIT W/O SAVE
DOME SETUP
EXIT
Menu Description Options Default
Input Defines the type of physical
input.
NC - Normally Closed
NO - Normally Open
OFF - Alarm input is disregarded
OFF
Option Defines the mode of operation. Time Out - Upon alarm activation, the cam-
era moves to the defined preset and
remains in alarm for the specified dwell
time. When the time has expired the cam-
era reverts back to the previous operation
prior to the alarm being activated.
Momentary - Upon alarm activation, the
camera moves to the pre-defined preset
position and remains in alarm mode until
OFF + 65 + ENTER is pressed. After the
alarm is acknowledged, the camera reverts
back to the previous operation prior to the
alarm being activated.
Time Out
Preset Moves to the defined preset,
upon alarm activation,
All saved presets are available. 1
Dwell Time In time out mode, the camera
remains in alarm mode for the
specified dwell time.
Allows a range of 5-99 sec. 5
Save and Exit Saves and exits the menu.
Exit W/O Save Exits the menu without saving the
data.