The Tape / direct switch selects between monitoring the Audio signal before the tape or after the tape (off-tape-
monitoring). This allows you to immediately check the recorded program material, provided your recorder has the
tape monitoring feature. A Dip switch provides you with the choice of a manual or an automatic Tape/direct
function. In manual mode you use the tape direct switch to listen either before or after the tape. In automatic mode
as soon as you press the roll button you monitor the signal from tape and as you press stop the direct signal. (DIP
mini-switch 1 off auto/ on manual).
The Tape return rotary switch on the extension box selects the tape return source.
Configurations:
DIP Switch S-1
Wiring of the 6 Neutrik connector (Boom Box connection)
Jumper positions:
{
JP-1 48 Volts ON-OFF (Factory setting off)
{
JP-4 Pre or post mic level Sidetone pos. 1-2=pre / pos. 2-3 post (Factory setting post)
{ JP-9 Slate to AUX bus (Factory setting on)
The SX-S Extension Module is available in various configurations. It will occupy two spaces in the mixer.
6.15 SX022241 SX-S Stereo analog level & Phase meter
This module consists of two very high quality meter movements for the Left and Right channels. The meter scales
can be illuminated with two intensities. The meters can be switched to indicate as VU meters or as peak-meters.
They can also be switched between mono and stereo. In mono mode the left meter functions as a phase
correlation meter while the right channel meter always indicates the greater of the two signals. LEDs indicate
which channel is the greater.
6.16 SX022270 SX-S Extension module
This module contains the SX022241 Stereo Analog Level & Phase Meter, plus the monitoring and communication
functions, (including MS decoding). It is shipped with the necessary Neutrik 6-pin chassis connector (SX860180)
for connection to the SX-S Boom Box (SX022260) and the 12-pin chassis connector (SX860208) for connection to
the SX-S Extension Box. (SX022251). It also includes the necessary mounting hardware and connectors for
Position
Function
Factory Setting
Switch
1 Manual / Tape direct Automatic Off
2
Boom active
Switched
Off
3 Call LED momentary Lamp on Off
4
27 Hz Slate tone
Off
Off
Pin nb
Cable nb
Cable
Function
6 2 Cable call (GND) CALL
5 2 Brown Hi Mic Boom
4 2 White Low Mic Boom
3 1 GND GND
2 1 Red Right channel H.phones
1 1 White Left Channel H.phones