To make the external slate Mic operational you will need to solder in R-7=15kOhms (R-5=49.9) and C-11=22pF
remove R-10 on the extension module operator board. Unsolder the internal mic on Connectors J-10 & J-11.
Then connect J-12 to the Bantam jack. Make sure that Jumper 2 is in position 2,3.
NOTE:
The internal Slate Mic is deactivated by this procedure.
SX-S10 only: Remove the unused wire on the Bantam connector.
7.4 Y Cables for Boom Operator with tbk mic transmitter.
Click here for DIAGRAMof "Y" Cable
Internal connections of the Boom-Box (022260)
Click here for BOOM BOX Wiring Diagram
922110 External cable between SX-S extension module and SX-S extension box
Click here for MALE and FEMALE Socket Wiring
RETURN TO TABLE OF CONTENTS
860162 860179 860141
Pin No
Cable Pin No Cable Pin
1 White Tip White
2
White
Ring
Red
1
GND
Black
3
White
GND
GND
3
White
Black
4
2 Red Black 5
6
Pin No Pair No Cable Designation
12 4 Shield GND
11 4 White -12V
10 4 Yellow +12V
9 3 Orange Guest
8 3 White Roll
7 3 Shield 12V micro
6 2 Red Right from Ext. Box
5 2 White Left from Ext. Box
4
2
Shield
GND from Ext. Box
3 1 Brown Right to Ext. Box
2
1
White
Left to Ext. Box
1 1 Shield GND to Ext. Box
Seite 17 von 22SONOSAX SX/S USER MANUAL
26.08.2004file://D:\Z
_