HONEYWELL™ Wind Turbine WT6500 Owner’s Manual - Rev 10
Turbine Installation
Figure 2.11 Turbine Connection Location in SMARTBOX™ Controller
Turbine Over-Current Protection
The NEC/CEC requires the turbine circuit to be protected with a device rated for 125%
of the rating of the circuit. The DC-rated fuse or circuit breaker between the turbine
and the SMARTBOX™ Controller must have a maximum size of 15 (the maximum
current rating of the Smart Box).
SHOCK OR FIRE HAZARD
Over-current protection must be installed to protect the
Smart Box from short circuits and to provide a means of
disconnecting the it.
REVERSE POLARITY DAMAGE
Before making the nal DC connection or closing the DC
breaker or disconnect, check cable polarity at both the
battery and the Smart Box. Positive (+) must be connected
to positive (+). Negative(-) must be connected to negative
(-).