DX8 – 35
DX-SW4 Remote Switch Control (4-button/4-LED)
Switch Positions
ID 1 through 8 Function Control 1 Control 2 Control 3 Control 4
0 00000000 Mute Input 1-4 (1) Mute Input 1 Mute Input 2 Mute Input 3 Mute Input 4
1 10000000 Mute Input 1-4 (2) Mute Input 1 Mute Input 2 Mute Input 3 Mute Input 4
2 01000000 Mute Input 5-8 (1) Mute Input 5 Mute Input 6 Mute Input 7 Mute Input 8
3 11000000 Mute Input 5-8 (2) Mute Input 5 Mute Input 6 Mute Input 7 Mute Input 8
4 00100000 Mute Group 1-4 (1) Mute Group 1 Mute Group 2 Mute Group 3 Mute Group 4
5 10100000 Mute Group 1-4 (2) Mute Group 1 Mute Group 2 Mute Group 3 Mute Group 4
6 01100000 Mute Group 5-8 (1) Mute Group 5 Mute Group 6 Mute Group 7 Mute Group 8
7 11100000 Mute Group 5-8 (2) Mute Group 5 Mute Group 6 Mute Group 7 Mute Group 8
8 00010000 Force On 1-4 (1) Force On 1 Force On 2 Force On 3 Force On 4
9 10010000 Force On 1-4 (2) Force On 1 Force On 2 Force On 3 Force On 4
10 01010000 Force On 5-8 (1) Force On 5 Force On 6 Force On 7 Force On 8
11 11010000 Force On 5-8 (2) Force On 5 Force On 6 Force On 7 Force On 8
12 00110000 Force Off 1-4 (1) Force Off 1 Force Off 2 Force Off 3 Force Off 4
13 10110000 Force Off 1-4 (2) Force Off 1 Force Off 2 Force Off 3 Force Off 4
14 01110000 Force Off 5-8 (1) Force Off 5 Force Off 6 Force Off 7 Force Off 8
15 11110000 Force Off 5-8 (2) Force Off 5 Force Off 6 Force Off 7 Force Off 8
16 00001000 Preset Recall 1-4 (1) Preset Recall 1 Preset Recall 2 Preset Recall 3 Preset Recall 4
17 10001000 Preset Recall 1-4 (2) Preset Recall 1 Preset Recall 2 Preset Recall 3 Preset Recall 4
18 01001000 Preset Recall 5-8 (1) Preset Recall 5 Preset Recall 6 Preset Recall 7 Preset Recall 8
19 11001000 Preset Recall 5-8 (2) Preset Recall 5 Preset Recall 6 Preset Recall 7 Preset Recall 8
20-255 For Future Updates
Appendix C: Selection Remote Predefined Functions
Appendix D: Level Remote Predefined Functions
DX-RVC Remote Volume Control (2-button/12-LED)
Switch Positions
ID 1 through 8 Function
0 00000000 Input Level 1A (1)
1 10000000 Input Level 1A (2)
2 01000000 Input Level 1B (1)
3 11000000 Input Level 1B (2)
4 00100000 Input Level 2A (1)
5 10100000 Input Level 2A (2)
6 01100000 Input Level 2B (1)
7 11100000 Input Level 2B (2)
8 00010000 Input Level 3A (1)
9 10010000 Input Level 3A (2)
10 01010000 Input Level 3B (1)
11 11010000 Input Level 3B (2)
12 00110000 Input Level 4A (1)
13 10110000 Input Level 4A (2)
14 01110000 Input Level 4B (1)
15 11110000 Input Level 4B (2)
16 00001000 Input Level 5A (1)
17 10001000 Input Level 5A (2)
18 01001000 Input Level 5B (1)
19 11001000 Input Level 5B (2)
20 00101000 Input Level 6A (1)
21 10101000 Input Level 6A (2)
22 01101000 Input Level 6B (1)
23 11101000 Input Level 6B (2)
24 00011000 Input Level 7A (1)
25 10011000 Input Level 7A (2)
26 01011000 Input Level 7B (1)
27 11011000 Input Level 7B (2)
28 00111000 Input Level 8A (1)
29 10111000 Input Level 8A (2)
30 01111000 Input Level 8B (1)
31 11111000 Input Level 8B (2)
32 00000100 Output Level A (1)
33 10000100 Output Level A (2)
34 01000100 Output Level B (1)
35 11000100 Output Level B (2)
36 00100100 Output Level A&B (1)
37 10100100 Output Level A&B (2)
38 01100100 Group Level 1 (1)
39 11100100 Group Level 1 (2)
40 00010100 Group Level 2 (1)
41 10010100 Group Level 2 (2)
42 01010100 Group Level 3 (1)
43 11010100 Group Level 3 (2)
44 00110100 Group Level 4 (1)
45 10110100 Group Level 4 (2)
46 01110100 Group Level 5 (1)
47 11110100 Group Level 5 (2)
48 00001100 Group Level 6 (1)
49 10001100 Group Level 6 (2)
50 01001100 Group Level 7 (1)
51 11001100 Group Level 7 (2)
52 00101100 Group Level 8 (1)
53 10101100 Group Level 8 (2)
54-255 Reserved for future
updates
Switch Positions
ID 1 through 8 Function
Each of the predefined functions has two IDs (1) and (2) to allow two remote controls
to perform the same function.