Behringer DCX2496 DJ Equipment User Manual


 
14 ULTRADRIVE PRO DCX2496 User Manual
4.3.4 DYNAMIC EQ (FILTER)
As the DYNAMIC EQ is a highly complex module, its parameters are allocated to
two pages—the FILTER and the DYNAMICS parameters pages.
The DYNAMIC EQ inuences a specic frequency range of the signal, depending
on the volume level. It can either boost or cut this frequency range, depending
on the gain setting made by the user. If the gain control is set to lower the
respective frequency range in level, and if a preset THRESHOLD is exceeded, the
EQ modies the sound by reducing the gain of the frequency range. The amount
of gain reduction applied is dened by the RATIO value. When the signal drops
below threshold again, the frequency range is “smoothed out” again, i.e. the
DYNAMIC EQ stops processing the signal.
When you dene a certain boost with the GAIN control, the gain of the
frequency range is raised depending on the volume level. When the level of
the selected frequency range drops below a preset THRESHOLD, the range is
boosted by a certain amount (RATIO). As soon as the threshold is exceeded again,
the DYNAMIC EQ stops processing the signal.
Fig. 4.34: In A Dynamic EQ ( Filter)
The complete DYNAMIC EQ (FILTER) page corresponds to the EQ page in
terms of operation and to the parameters in terms of number and type.
Exception: Onlyone lter is selectable.
4.3.5 DYNAMIC EQ DYNAMICS
On this page you can edit both the threshold and the operating mode of the
compressor and/or expander (volume-dependent sound processing).
Fig. 4.35: In A Dynamic EQ ( Dynamics)
The THRESHOLD parameter denes a threshold, activating the lter function
once that threshold is exceeded. If the lter has been set to reduce the gain
on the DYNAMIC EQ (FILTER) page (GAIN < 0), this frequency range will be cut,
assoon as it exceeds the threshold.
However, if the lter has been set to raise the gain (GAIN > 0), the frequency
range is boosted, as soon as its level drops below the threshold. The threshold
setting range is from -60 to 0 dB.
Next, you can use the RATIO parameter to dene the amount of gain
boost/cut. RATIO adjusts the level balance between the input and output
signals. Available settings range from 1.1 : 1 (minimum boost/cut) to ∞ :
1 (maximum boost/cut).
ATTACK denes how fast the DYNAMIC EQ reacts to signals exceeding or falling
below THRESHOLD, and can be set from
1 to 200 milliseconds.
RELEASE controls the recovery time needed by the EQ to stop processing the
signal, once it has exceeded or fallen below THRESHOLD (depends on the GAIN
setting). Available RELEASE times are from 20 to 4,000 milliseconds.
Settings
TYPE BP
FREQ 1.00 kHz
GAIN
+15 dB > continuous line
0 dB > broken line
-15 dB > dotted line
Q 0.1
THRESHOLD -40 dB
RATIO ∞ : 1
Tab. 4.3: Band-pass settings with extreme values (results in g. 4.36)
0
dBu
-40
dBu
Positive gain >
gain boost
after dropping
below threshold
Negative gain >
gain reduction
after exceeding
threshold
-40 dBu
Threshold
0
dBu
Fig. 4.36: Filter curves with gain above/below threshold
4.4 SUM menu
In addition to its inputs A-C, the ULTRADRIVE PRO DCX2496 provides an internal
source signal that can be composed of these three input signals. This SUM signal
can be edited at any time, much like any other input signal, so that you have a
maximum of four separate source signals available.
4.4.1 INPUT/GAIN
Fig. 4.37: Sum Input/Gain
In this menu, the parameter IN SELECT allows you to dene a combination of
two inputs forming the SUM signal. Available options are: IN A + IN B, IN A +
IN C and IN B + IN C. Of course, you can also use just one input signal as your
SUM signal (IN A, IN B or IN C), by doubling one of the inputs. It is impossible,
however, to form a SUM signal composed of all input signals!
If no additional source signal is required, set IN SELECT to OFF. The current SUM
conguration is shown graphically below this parameter.
In the top left corner of the display you can use SUM INPUT Gains to adjust
the input signal of the inputs A-C. The signal controlled here is taken directly
from post-input converters—not post-EQ or post-Dynamics. Therefore, it is not
necessary to re-adjust the input gain. The SUM INPUT GAINS setting range is from
-15 to +15 dB.
With the OUT GAIN parameter you can control the internal output level of
the sum signal. This signal is also taken pre-EQ, pre-Dynamics, etc. and is then
routed to output channels 1-6. The gain setting also ranges from -15 to +15 dB.
Thus,you can use one parameter to quickly adjust all inputs together in their
adjusted balance at the same time.