18 ULTRADRIVE PRO DCX2496 User Manual
Fig. 4.55: Store ➠ Copy
◊ Locked DESTINATION PRESETS cannot be overwritten. In this case,
the display informs you that the process cannot be completed.
Since SOURCE PRESETS will not get lost during the copying process,
it does not matter whether they are locked or not.
When all settings have been made and conrmed with OK, the DESTINATION
PRESET is directly overwritten and the display indicates the name of the new
preset. Locked SOURCE PRESETS are stored as unlocked presets. To lock them,
goto the next page of the STORE menu (PRESET-LOCK). You can also unlock
locked DESTINATION PRESETS there.
Fig. 4.56: Store ➠ Copy
Additionally, you can copy all presets in one operation, by selecting ALL PRESETS
in both SOURCE and DESTINATION PRESETS. Prior to that, all presets in the
destination memory must be unlocked. When you conrm with OK, the displays
warns you that all DESTINATION PRESETS will be overwritten.
Fig. 4.57: Store ➠ Copy
Press OK to complete the process, or CANCEL to quit.
◊ It is impossible to copy a bank to the same memory location
(e.g. ALL INTERNAL PRESETS to ALL INTERNAL PRESETS).
4.8.4 PRESETLOCK
Fig. 4.58: Store ➠ Preset-Lock
The last page of the STORE menu allows you to LOCK or UNLOCK your presets.
SELECT selects the corresponding bank (INT or CARD), the right-hand window
displays the preset. Use ALL PRESETS to select all presets. Press OK to lock the
preset, or CANCEL to unlock it.
Here, you can unlock a DESTINATION PRESET you wish to overwrite, or lock
recently copied presets.
5. Audio Connections
The BEHRINGER ULTRADRIVE PRO DCX2496 has standard electronically balanced
inputs and outputs. The circuit design has an automatic hum suppression with
balanced signals and is able to operate, without problem, even at highest
levels. Externally-induced mains hum etc. is thus eciently suppressed.
Theservo-function, also automatic, recognizes the connection of unbalanced
pin assignments and changes the nominal level internally so that there is no
dierence in level between the input and output signals (6dB correction).
◊ Please ensure that only qualified persons install and operate the
device. During installation and operation the user must have sufficient
contact to earth. Electrostatic discharges might affect the operation of
the unit.
output
For unbalanced use, pin 1 and pin 3
have to be bridged
1 = ground/shield
2 = hot (+ve)
3 = cold (-ve)
input
12
3
1
2
3
Balanced use with XLR connectors
Fig. 5.1: XLR connections
6. Applications
On the following pages we present the most useful applications for your
ULTRADRIVE PRO, using a few practical examples. For each example there is
an appropriate preset available, which you can use as a starting point for your
own set-ups.
Please note that these presets provide only basic outline settings that must
be adapted to meet your specic requirements in terms of loudspeaker,
amplierand room acoustics!
The application examples are arranged in three groups:
1. Classic setups (chapters 6.1 – 6.6)
2. Special applications: zoning / delay lines / surround
(chapters 6.7 – 6.9)
3. Large-scale applications requiring two DCX (chapters 6.10 – 6.12)