Lexicon PCM96 DJ Equipment User Manual


 
30
MIdI SySex IMPLeMeNtAtIoN
coMMANd 0: ReQUeSt PReSet dUMP
When this command is received by the PCM96, it will respond with a preset
dump of the requested preset. If the preset does not exist, the PCM96 will
not respond. Only presets from User banks may be requested. Factory banks
will not be transmitted.
Byte Definition Comments
0xF0 Sysex message
0x06 Lexicon
®
Manufacturer ID
0x__ Product ID
0x__ Device ID
0x00 Command Request Preset Dump
0x02 Size LSB
0x00 Size cont
0x00 Size cont
0x00 Size MSB
0x__ Bank Bank in which requested preset
lives.
0x__ Preset Preset ID
0xF7 EOX
coMMANd 1: PReSet dUMP
This sysex is transmitted by a MIDI sequencer or by PCM96. The PCM96
may transmit this dump in response to a request or by means of a front-
panel action. The PCM96 receiving this dump will store the encapsulated
preset data in the designated location.
Byte Definition Comments
0xF0 Sysex message
0x06 Lexicon Manufacturer ID
0x__ Product ID
0x__ Device ID
0x01 Command Preset Dump
0x__ Size LSB. Size is variable and is not shown in this
example
0x__ Size cont
0x__ Size cont
0x__ Size MSB
0x__ Bank Bank in which the preset is to be placed.
0x__ Preset Location in the bank where the preset is to
be placed.
... Preset data Nibbleized preset data.
0xF7 EOX