Roland FC-200 Music Pedal User Manual


 
44
EDIT PARAMETERS (Bulk area)
Address(H) Size(H) Data(H) Parameter Description
——————————————————————————————
10 00 00 1E Edit Parameters *1 1 packet
11 00 00 1E Factory Preset *2 1 packet
Only the above-mentioned address can be used as the start address.
*1 Output during Bulk Dump operation.
Also outputs upon receiving Data Request RQ1.
The value of Edit parameter is changed upon receiving Data Set DT1.
*2 Default data of Edit parameter value.
Outputs when Data Request RQ1 is received.
Data Set DT1 is ignored.