Messages and Error Messages
This section lists the messages (error messages) that the TD-12 produces and explains the meaning of each
message, giving you the appropriate action to take.
fig.Message_70
When an indication of “ACCEPT” is shown above [F5] as in the
figure, pressing that button will close the message window.
Error Messages
Message
Meaning Action
Backup Battery Low!
The internal backup battery of the TD-12 (a
battery that maintains data in the user mem-
ory) has run down.
Contact your dealer or a nearby Roland service
center to have the battery replaced.
Backup NG! Data in the TD-12’s memory may be corrupt-
ed. The TD-12’s internal backup battery (the
battery used for saving User memory data) is
fully drained; internal data has been lost.
Contact your dealer or a nearby Roland service
center to have the battery replaced. Follow the
messages appearing on the screen to carry out
Factory Reset (p. 79); you will then be able to
use the unit temporarily.
MIDI Communication Error! It is possible that the power has been turned
off for the MIDI device connected to the TD-
12’s MIDI IN connector.
Check the power of the connected MIDI de-
vice.
System Error! A problem has occurred with the internal
system.
Contact your dealer or a nearby Roland service
center.
Measure Maximum! The maximum number of measures that can
be recorded to one pattern has been exceed-
ed; no further recording or editing that adds
measures can be carried out.
Delete unneeded measures from the pattern
being recorded or edited (p. 69).
Data Overload! Pattern contained an excessive amount of da-
ta, and as a result could not be output suc-
cessfully from MIDI OUT.
Try eliminating a part that has too much data.
Not Enough Memory! Pattern recording or editing could not be car-
ried out because there was not enough inter-
nal memory.
Try deleting patterns that are no longer needed
(p. 69).
BULK DUMP
Checksum Error!
The checksum value of a system exclusive
message was incorrect.
Correct the checksum value.
BULK DUMP
Receive Address Error!
The receive address of a system exclusive
message was incorrect.
Correct the receive address.
BULK DUMP
Receive Data Error!
A MIDI message was received incorrectly. If the same error message is displayed repeat-
edly, there is a problem with the MIDI messag-
es that are being transmitted to the TD-12.
BULK DUMP
Receive Time Out!
The interval in receiving system exclusive
messages were too long.
Make the interval of the data shorter.
TD-12_e.book 82 ページ 2005年5月31日 火曜日 午後1時32分