Sony SRP-X500P Musical Instrument User Manual


 
SRP-X500P RS-232C Interface Manual
PROJECTOR PROTOCOL SWITCH (1st byte)
SYSTEM TYPE SWITCH (2nd byte)
Shows the position of the PROJECTOR PROTOCOL selector or the SYSTEM TYPE selector on the
front panel of the SRP-X500P.
The parameters and the switch position are shown in the following table.
SWITCH
0 0x30 (‘0’)
1 0x31 (‘1’)
2 0x32 (‘2’)
3 0x33 (‘3’)
4 0x34 (‘4’)
5 0x35 (‘5’)
6 0x36 (‘6’)
7 0x37 (‘7’)
8 0x38 (‘8’)
9 0x39 (‘9’)
A 0x3A (‘:’)
B 0x3B (‘;’)
C 0x3C (‘<‘)
D 0x3D (‘=‘)
E 0x3E (‘>‘)
F 0x3F (‘?’)
INPUT VOLUME (3rd-8th byte)
Shows the setting of the input level controls on the front panel of the SRP-X500P.
Byte Parameter
1st MIC 1/WL 1 INPUT VOLUME
2nd MIC 2/WL 2 INPUT VOLUME
3rd MIC 3 INPUT VOLUME
4th MIC 4 INPUT VOLUME
5th LINE INPUT VOLUME
6th AV/RGB INPUT VOLUME
The correspondence of the parameter with the level setting is the same as that of the FADER
parameter of the INPUT FADER command (page 7).
MASTER VOLUME LEVEL (9th byte)
Shows the setting of the MASTER control on the front panel of the SRP-X500P.
The correspondence of the parameter with the level setting is the same as that of the FADER
parameter of the INPUT FADER command (page 7).
REMOTE 1-6 LEVEL (10th-15th byte)
Shows the level of the REMOTE 1-6 faders.
The correspondence of the parameter with the level setting is the same as that of the LEVEL
parameter of the REMOTE 1-6 LEVEL command (page 10).
Page 26/43