Sony SRP-X500P Musical Instrument User Manual


 
SRP-X500P RS-232C Interface Manual
FR (50th-53rd byte)
The FR parameter consists of the 4 bytes of data in the order shown in the following table.
Byte Parameter
1st MIC 1/WL 1 FR
2nd MIC 2/WL 2 FR
3rd MIC 3 FR
4th MIC 4 FR
FR
Shows the status of the FEED BACK REDUCER. The correspondence of the parameter with
the FEED BACK REDUCER setting is shown in the following table.
FR
Turned off 0x30 (‘0’)
Turned on 0x31 (‘1’)
Setting up in progress 0x32 (‘2’)
Cancellation in progress 0x33 (‘3’)
FR SETUP STATUS (54th and 55th byte)
The FEED BACK REDUCER setup status parameter consists of the 2 bytes of data in the order shown
in the following table.
Byte Parameter
1st SETUP CHANNEL
2nd SETUP STATUS
SETUP CHANNEL
Shows the channel for which the FEED BACK REDUCER setting is in progress.
The parameter and the channel are shown in the following table.
Channel
Normal operation 0x30 (‘0’)
MIC 1/WL 1 0x31 (‘1’)
MIC 2/WL 2 0x32 (‘2’)
MIC 3 0x33 (‘3’)
MIC 4 0x34 (‘4’)
CANCEL 0x35 (‘5’)
Page 31/43