Sony SRP-X500P Musical Instrument User Manual


 
SRP-X500P RS-232C Interface Manual
2.1.5 OUTPUT FADER : 0x43 0x50 0x4D 0x40 (‘CPM@’)
This command is used to set the level of the output faders.
The parameter specified by this command functions in the same way as the output faders in the OVER
VIEWscreen of the SRP-X500P Manager.
Packet format
0x43 0x50 0x4D 0x40 parameter” 0x0D
Parameter
The parameter consists of 8 bytes of data in the order shown in the following table.
Byte Parameter
1st SPEAKER OUTPUT 1 FADER
2nd SPEAKER OUTPUT 2 FADER
3rd SPEAKER OUTPUT 3 FADER
4th SPEAKER OUTPUT 4 FADER
5th LINE OUTPUT 1 FADER
6th LINE OUTPUT 2 FADER
7th LINE OUTPUT 3 FADER
8th LINE OUTPUT 4 FADER
FADER (1st-8th byte)
The level for each output fader can be specified (in dB units).
The correspondence of the parameter with the level meter setting is the same as that of the
FADER parameter of the INPUT FADER command (page 7).
Example
To specify the level for each output fader as follows:
SPEAKER OUTPUT 1 FADER : -10dB
SPEAKER OUTPUT 2 FADER : -10dB
SPEAKER OUTPUT 3 FADER : -10dB
SPEAKER OUTPUT 4 FADER : -10dB
LINE OUTPUT 1 FADER : 0dB
LINE OUTPUT 2 FADER : 0dB
LINE OUTPUT 3 FADER : 0dB
LINE OUTPUT 4 FADER : 0dB
0x43 0x50 0x4D 0x40 0x4A 0x4A 0x4A 0x4A 0x59 0x59 0x59 0x59 0x0D
(‘C P M J J J J Y Y Y Y CR’)
2.1.6 OUTPUT FADER REQUEST : 0x52 0x50 0x4D 0x40 (‘RPM@’)
This command is used to read the output fader settings of the SRP-X500P.
Packet format
0x52 0x50 0x4D 0x40 0x0D