Yamaha DSP5D Music Mixer User Manual


 
PM5D/PM5D-RH V2 / DSP5D Owner’s Manual Reference section 291
Information shown
in the display
Function
menu
Global
functions
Output
functions
Input
functions
Appendices
K FILTER ON/OFF
This is an on/off switch for the filter applied to the key-
in signal.
L CUE
This button cue-monitors the currently selected key-in
signal.
Note
Even if the cue mode is set to MIX CUE (which lets you moni-
tor the mix of all channels whose [CUE] key is on), only the
corresponding signal will take priority for monitoring when you
turn on the CUE button in the GATE PARAM screen. (Any
[CUE] keys that had been on at that time will be forcibly turned
off.)
M THRESHOLD (Threshold level)
Specifies the level at which the gate will open and close.
The gate will open when the key-in signal exceeds this
level, and will close when the signal falls below this
level.
N ATTACK (Attack time)
Specifies the time from when the key-in signal exceeds
the threshold level until the gate opens.
O HOLD (Hold time)
Specifies the time that the gate will remain open after
the key-in signal falls below the threshold.
P DECAY (Decay time)
Specifies the time over which the gate will close after
the hold time has elapsed.
Q RANGE
Specifies the amount of attenuation while the gate is
closed.
Here you can edit the compressor parameters of the
selected input channel.
A Channel selection
Select the input channel (input channel, ST IN chan-
nel) that you want to edit.
B Name
This is the name of the currently selected input chan-
nel. If the input channel is paired (or if a ST IN channel
is selected), a heart symbol is displayed at the right. For
an input channel, you can click this symbol to enable/
disable pairing.
C COMP ON/OFF (Compressor on/off)
Turns the compressor on/off for that channel.
D COMP LINK GROUP (Compressor link
group)
Selects the compressor link group (1–8) to which that
channel belongs. Compressor parameters are linked for
input channels belonging to the same group.
Note
Input channel compressor link groups are independent from
output channel compressor link groups.
E LIBRARY
This button accesses the COMP LIBRARY screen
( p.256), where you can store/recall compressor
library settings for input channels.
M N O P Q
COMP PARAM (Compressor parame-
ter) screen
COMP PARAM
1 2 3 54