Yamaha MU100R Musical Instrument User Manual


 
32
MIDI
Control# Parameter Data Range
120 All Sound Off 0
1.3.2 Reset All Controllers
This message resets the following controllers to their default
values.
Controller Value
Pitch bend change ±0 (center)
Channel pressure 0 (off)
Polyphonic key pressure 0 (off)
Modulation 0 (off)
Breath control 127 (maximum)
Foot control 127 (maximum)
Expression 127 (maximum)
Control change13 ±0 (center)
Hold 0 (off)
Portamento 0 (off)
Sostenuto 0 (off)
Soft pedal 0 (off)
Portamento control Reset the portamento source
note number that was received
RPN Number unset, internal data is
not affected.
NRPN Number unset, internal data is
not affected.
The following data is not changed
Parameter values specified by program change, bank select
MSB/LSB, volume, pan, effect send levels 1, 3, 4, RPN and
NRPN.
Control# Parameter Data Range
121 Reset All Controllers 0
1.3.3 All Note Off
This message turns off all notes which are currently on for
the corresponding part.
However, if Hold 1 or Sostenuto are on, notes will continue
to sound until these are turned off.
Control# Parameter Data Range
123 All Note Off 0
1.3.4 Omni Off
Perform the same processing as when All Note Off is
received.
Control# Parameter Data Range
124 Omni Off 0
1.3.5 Omni On
Perform the same processing as when All Note Off is
received.
Control# Parameter Data Range
125 Omni On 0
1.3.6 Mono
Perform the same processing as when All Sound Off is
received, and if the value (mono number) is in the range of
0...16, set the corresponding channel to Mode4* (m = 1).
Control# Parameter Data Range
126 Mono 0...16
* Mode4 is a state in which only channel messages on the
specified channel will be received, and notes will be
sounded individually (monophonically).
1.3.7 Poly
Perform the same processing as when All Sound Off is
received, and set the corresponding channel to Mode3*.
Control# Parameter Data Range
127 Poly 0
* Mode3 is when channel messages will be received only
on the specified channel, and will be sounded
polyphonically.
1.4 Program change
This message is used to select voices or performances.
When this is transmitted in conjunction with Bank Select (see 1.2.1),
voices and performances can be selected not only from the basic voice
bank but also from the extended voice bank and from internal
performances.
If the Multi Part parameter Rcv PROGRAM CHANGE = OFF, that
part will not receive program changes.
If Sound Module Mode = C/M, program changes for the Drum Part
will not be received.
1.5 Pitch bend
This message conveys movements of the pitch bender.
This message is generally used to modify the pitch of a part, but the
depth of the following seven effects can be controlled.
The effect of this message can be modified by the following parameters.
• Multi Part Parameter
1. BEND PITCH CONTROL
2. BEND FILTER CONTROL
3. BEND AMPLITUDE CONTROL
4. BEND LFO PMOD DEPTH
5. BEND LFO FMOD DEPTH
6. BEND LFO AMOD DEPTH
• Effect1 Parameter
7. BEND VARIATION CONTROL DEPTH
(Valid when Variation Effect is assigned to a part as Insertion)
By default, the Pitch Control effect is applied.
If the receive channel is a drum part, effects 5 and 6 will not
apply.
If the Multi Part parameter Rcv PITCH BEND CHANGE =
OFF, that part will not receive pitch bend messages.