Yamaha MU100R Musical Instrument User Manual


 
36
MIDI
For parameters whose Data Size is 2 or 4, the number of
data bytes indicated by Size are transmitted.
2.1.5.1 Current Performance parameter
change
This message sets the CURRENT PERFORMANCE
block (refer to tables <3 - 1>, <3 - 2>).
2.1.6 VL70-m native parameter changes
11110000 F0H Exclusive status
01000011 43H YAMAHA ID
0001nnnn 1NH N:Device Number
01010111 57H Model ID
0ggggggg GGH Address High
0mmmmmmm MMH Address Mid
0lllllll LLH Address Low
0vvvvvvv VVH Data
: :
11110111 F7H End of Exclusive
2.1.6.1 VL System parameter change
(refer to table <4 - 1>).
2.1.6.2 VL Current Voice/Common
Misc parameter change
(refer to
table <4 - 2>).
2.1.6.3 VL Part parameter change
(refer
to table <4 - 3>).
2.1.6.4 VL Current Voice/Element
parameter change
(refer to table
<4 - 4>).
2.1.7 Other parameter changes
2.1.7.1 Master tuning
This message simultaneously modifies the tuning
of all channels.
11110000 F0H Exclusive status
01000011 43H YAMAHA ID
0001nnnn 1NH N:device Number
00100111 27H Model ID
00110000 30H Address High
00000000 00H Address Mid
00000000 00H Address Low
0000mmmm 0MH Master Tune MSB
0000llll 0LH Master Tune LSB
0xxxxxxx XXH don't care
11110111 F7H End of Exclusive
Normally, the XG SYSTEM message MASTER TUNE
should be used (refer to table <1-2>).
2.2 Bulk dump
This device uses the following bulk dump messages.
[XG BULK DUMP]
1) XG System bulk dump
2) System Information bulk dump
3) Multi Effect1 bulk dump
4) Multi EQ bulk dump
5) Multi Effect2 bulk dump
6) Multi Part bulk dump
7) AD Part bulk dump
8) Drums Setup bulk dump
[MU100 NATIVE BULK DUMP 1]
1) MU100 System bulk dump
2) MU80, MU50 Internal Performance bulk dump
[MU100 NATIVE BULK DUMP 2]
1) MU100 Internal Performance bulk dump
[VL70-m NATIVE BULK DUMP]
1) VL System bulk dump
2) VL Current Voice/Common Misc bulk dump
3) VL Part bulk dump
4) VL Current Voice/Element bulk dump
5) VL Custom Voice bulk dump
6) VL Internal Voice bulk dump
2.2.1 XG bulk dump
This message sets XG-related parameters. Unlike parameter
change messages, a single message can modify multiple
parameters. The message format is as follows.
11110000 F0H Exclusive status
01000011 43H YAMAHA ID
0000nnnn 0NH N:Device Number
01001100 4CH Model ID
0sssssss SSH ByteCountMSB
0ttttttt TTH ByteCountLSB
0ggggggg GGH Address High
0mmmmmmm MMH Address Mid
0lllllll LLH Address Low
0vvvvvvv VVH Data
: :
0kkkkkkk KKH Check-sum
11110111 F7H End of Exclusive
Address and Byte Count are given in tables 1-n. Byte Count
is indicated by the total size of the Data in tables 1-n.
Bulk dump and dump request messages are received when
the beginning of the block is specified as the 'Address'.
'Block' indicates the unit of the data string that is indicated
in tables 1-n as 'Total size'.
Check sum is the value that produces a lower 7 bits of 0
when the Start Address, Byte Count, Data, and the Check-
sum itself are added.
2.2.1.1 XG System bulk dump
This message sets the XG SYSTEM block (refer
to tables <1 -1>, <1 - 2>).
MIDI data format