Yamaha MU100R Musical Instrument User Manual


 
MIDI
55
3n rr 50 1 00 - 7F
HIGH PASS FILTER CUTOFF FREQUENCY
-64...0...63 40
51 1 NOT USED --
TOTAL SIZE 2
3n rr 60 1 30 - 50 VELOCITY SENSE PITCH -16...0...16 depend on the note
61 1 30 - 50 VELOCITY SENSE LPF CUTOFF -16...0...16 ˝
TOTAL SIZE 2
n:Drum Setup Number (0 - 3)
rr:note number (0D - 5B)
In the following cases, the MU100R will initialize all Drum Setups.
XG SYSTEM ON received
GM SYSTEM ON received
DRUM SETUP RESET received (when in XG mode)
[Note]
When a part to which a Drum Setup is assigned receives a program change, the assigned Drum Setup will be initialized.
If the same Drum Setup is assigned to two or more parts, changes in Drum Setup parameters (including program changes) will
apply to all parts to which it is assigned.
< Table 1 - 13 >
MIDI Parameter Change table (PART ASSIGN)
Address Size Data Parameter Description Default value
(H) (H) (H) (H)
70 00 00 1 00 - 0F, 7F VL PART ASSIGN PART 1…16, OFF 0
TOTAL SIZE 1
< Table 2 - 1 >
MIDI data format
Address (H) Parameter
30 pp 00 System
pp 20 Effect
pp 70 EQ
MU80 Performance Common INT
pp:Performance#
Parmeter Bass Address
Model ID = 49
MU100 SYSTEM 00 00 00 System
REMOTE SWITCH 0A 00 00 Remote Switch
MU80 30 00 00 #1 Common
INTERNAL : :
PERFORMANCE 30 63 00 #100 Common
31 00 00 #1 Part1
: :
31 63 00 #100 Part1
32 00 00 #1 Part2
: :
32 63 00 #100 Part2
33 00 00 #1 Part3
: :
33 63 00 #100 Part3
34 00 00 #1 Part4
: :
34 63 00 #100 Part4
Parameter Description
Address
(H) (M) (L)
< Table 2 - 2 >
MIDI Parameter Change table (MU100 SYSTEM)
Address Size Data Parameter Description Default value
(H) (H) (H) (H)
00 00 00 1 00 - 01 MUTE LOCK OFF , ON 00
01 1 00 - 01 AD LOCK OFF , ON 00
02 1 00 - 01 EQ LOCK OFF , ON 00
03 1 00 - 01 Rcv GM EXCLUSIVE MESSAGE OFF , ON 01
04 1 00 - 01 Rcv BANK SELECT OFF , ON 01