168 CHAPTER 5: PATHBUILDER S330 DIAGNOSTICS AND PERFORMANCE STATISTICS
Queue 1 Over
Threshold
The congestion threshold for
Queue 1was exceeded.
Check and correct VC connections.
Check and adjust VI shaper values.
Check and adjust incoming traffic
volume. Check for faulty IMA links
which may reduce traffic handling for a
group.
Queue 2 Over
Threshold
The congestion threshold for
Queue 2was exceeded.
Check and correct VC connections.
Check and adjust VI shaper values.
Check and adjust incoming traffic
volume. Check for faulty IMA links
which may reduce traffic handling for a
group.
Queue 3 Over
Threshold
The congestion threshold for
Queue 3 was exceeded.
Check and correct VC connections.
Check and adjust VI shaper values.
Check and adjust incoming traffic
volume. Check for faulty IMA links
which may reduce traffic handling for a
group.
SAR Initialize Failure Problem with the SAR chip on
the MCPU. MCPU SAR failed
initialization.
Replace the unit.
System Clock
Reverted
The system clock has reverted
to a higher priority clock.
Information only. This alarm occurs
only if the Clock Mode is set to
Revertive on the System Clock
Configuration menu.
System power up System is powered up. Information only.
Write Session Taken
by Super User
A super user has changed a
read-only session to read-write.
Information only.
Table 26 MCPU and CTX Module (System) Alarms (continued)
Alarm Meaning Troubleshooting Steps