18 CHAPTER 1: SYSTEM DESCRIPTION
Table 5 PathBuilder S310 System Specifications
SYSTEM SPECIFICATIONS
Ethernet 10 Base T 1
V.35/RS422 1
T1/E1 UNI 1
Mechanical:
Shelf dimensions
19” rack mountable
Rack mount spacing
Cooling
Unit weight (approx.)
Shipping weight (approx.)
3.5” x 17” x 15.25” (H x W D)
Yes (with brackets)
2 RMS
2 fans @ 37 CRM each (deregulated 20%)
15 lbs. per shelf
20 lbs. per shelf
Input power requirements 90-264 VAC, 50-60 Hz (110/220 self sensing),
standard grounded outlet or -42 to -60 VDC
Power consumption 60 watts typical, 100 watts max
Maximum current 1.5A @110VAC
0.75A @ 220VAC
3A @ 48VDC
Environmental:
Operating temperature
Storage temperature
Humidity
Altitude
0°to 45° C
-40° to 70°C
95% @ +40°C (non-condensing)
14000 ft.
Regulatory compliance
Safety
Emissions
UL listed (1950, 3rd edition)
CSA 22.2
EN60950
FCC Part 68
FCC Part 15, Class A
Homologation Pending
STANDARDS
ATM Forum UNI 3.x, T1/E1 CES 2.0, IMA, ATM DXI 1.0
ANSI T1.403, T1.617 Annex D
TIA/EIA EIA232, RS-449/422/423, 366
AT&T Pubs 62411 and 54016
Frame Relay Forum FRF.5 and FRF.8
IETF RFCs 1213, 1211, 1483, 1490, 1406, 1493, 1643
MOTHERBOARD SPECIFICATIONS
Main microprocessor RISC
Memory usage Flash EPROM, 8Mbytes
DRAM, 16Mbytes
(continued)