40 CHAPTER 2: INSTALLATION
Figure 16 illustrates the power supply socket and fuse.
Figure 16 SuperStack II RPS Power Supply Socket and Fuse
The PathBuilder S330/S310 automatically adjusts to the supply voltage. The fuse is
suitable for both 110V AC and 220-240V AC operations.
To change the fuse, follow these steps:
1 Turn of the power and unplug the unit.
CAUTION: Ensure that the power cord is disconnected before opening the fuse
holder cover.
2 Release the fuse holder by gently levering a small screwdriver under the fuse
holder catch. Use only 2A anti-surge type fuses of the same type and manufacture
as the original.
3 Remove the old fuse and replace it with a new one.
4 Close the fuse holder.
Step 4: Connect I/O
Cabling
The PathBuilder S330/S310 ships with the standard interfaces installed. Unless you
have purchased optional modules, you do not need to install any additional
modules. For details about how to install the optional CBR, voice compression,
and DS3/E3 UNI modules, see “Step 1 (Optional): Install the Optional Modules in
the Unit” earlier in this chapter.
The following LEDs indicate the status of the PathBuilder S330/S310 as a whole.
(See Figure 17.)
Power (green)—Illuminates when the unit is turned on.
Status (green)—Illuminates when the CPU completes downloading and flashes
in normal state.
Alert (red)—Illuminates when a major alarm is detected in the unit. See
Chapter 5 for information about managing system alarms.
AC Power
Fuse
Spare fuse holder