ICP-CC404 | Installation Guide | 10.0 Dialer Reporting Formats
Bosch Security Systems, Inc. | 12/08 | F01U089401-02 45
Figure 6: Basic Pager Display
1 – Subscriber ID number
2 – Zone status
3 – System status
4 – 0 – Zone Normal
1– Alarm
2 – Manually Isolated
5 – 8 – Disarmed
9 – Armed
6 – 0 – Normal
1 – Panic/Duress
2 – Fire Alarm
3 – Medical Alarm
7 – 0 – AC Normal
1 – AC Failure
8 – 0 – System Normal
1 – System Fault
10.2 Basic Pager Display Information
Subscriber ID Number
This is the identification number of the control panel
and is programmed in Locations 034 to 039 for
Receiver 1 and Locations 074 to 079 for Receiver 2
(refer to Section 11.5 Subscriber ID Number for Receiver 1
and Receiver 2 on page 47). The pocket pager displays
only the last three digits of the Subscriber ID
Number.
Zone Status
The zone status display shows you the status of each
zone (1 to 8) of the control panel. Table 37 describes
each status number when displayed on a pocket
pager.
Table 37: Zone Status Display Descriptions
Status Zone Description
0 Zone normal
The zone is sealed.
1 Alarm
The zone is unsealed and in alarm.
2 Zone bypassed
A system operator manually isolated the
zone. Refer to Section 4.11 Isolating Zones
on page 21 for information about manually
isolate a zone(s) prior to arming the system
Refer to Section 15.1 Zone Status –
Bypass Reports on page 60 for more
information.
3 Zone trouble
A zone was left unsealed after the end of
Exit Time. Refer to Section 15.2 Zone
Status – Trouble Reports on page 60 for
more information.