A SERVICE OF

logo

ICP-CC404 | Installation Guide | 22.0 Programming Sheets
Bosch Security Systems, Inc. | 12/08 | F01U089401-02 91
Location
Function
Options/Notes
Default/
Programming Entry
The fifth and sixth locations of the output definition provide the time base multiplier. Enter a value between
01 and 99.
368 to 397
Outputs
(continued)
One Shot Mode
When you program the output polarity as one shot, the time base is multiplied by the time base multiplier.
For example, if the time base = 2 and the multiplier = 05, the output operates for 5 sec.
Pulsing Mode
When you program the output polarity as pulsing, the time base becomes the ON time and the multiplier
becomes the OFF time. The OFF time is the time base, which is multiplied by the multiplier. For example,
if you want the output to pulse 1 sec ON and 5 sec OFF, you would program time base as 2 and the
multiplier as 5.
4 1
398 to 399
Entry Time 1
Refer to page 70
Location 398: increments of 1 sec (0 to 15 sec)
Location 399: increments of 16 sec (0 to 240 sec)
8 2
400 to 401
Entry Time 2
Refer to page 71
Location 400: increments of 1 sec (0 to 15 sec)
Location 401: increments of 16 sec (0 to 240 sec)
12 3
402 to 403
Exit Time (AWAY/STAY Modes)
Refer to page 71
Location 402: increments of 1 sec (0 to 15 sec)
Location 403: increments of 16 sec (0 to 240 sec)
0 0
404 to 405
Entry Guard Time for STAY Mode
Refer to page 71
Location 404: increments of 1 sec (0 to 15 sec)
Location 405: increments of 16 sec (0 to 240 sec)
0 0
406 to 407
Delay Alarm Report Time
Refer to page 71
Location 406: increments of 1 sec (0 to 15 sec)
Location 407: increments of 16 sec (0 to 240 sec)
0 0
408 to 409
Sensor Watch Time
Refer to page 71
Location 408: increments of days (tens digit)
Location 409: increments of days (units digit)
0
410
Codepad Lockout Time
Refer to page 71
0 No lockout
1 to 15 Increments of 10 sec (10 sec to 150 sec)
5
411
Siren Run Time
Refer to page 71
0 No siren time
1 to 15 Increments of 1 min (1 min to 15 min)
7
412
Siren Sound Rate
Refer to page 71
0 to 15 (slowest to fastest frequency)
1
413
Auto Arming Pre-Alert Time
Refer to page 71
0 No pre-alert time
1 to 15 Increments of 5 min (5 min to 75 min)
0 0 0 0
414 to 417
Auto Arming Time
Refer to page 72
Location 414: Hour of day (tens digit)
Location 415: Hour of day (units digit)
Location 416: Minute of day (tens digit)
Location 417: Minute of day (units digit)
0 0 0 0
418 to 421
Auto Disarming Time
Refer to page 72
Location 418: Hour of day (tens digit)
Location 419: Hour of day (units digit)
Location 420: Minute of day (tens digit)
Location 421: Minute of day (units digit)
3
422
Kiss-Off Wait Time
Refer to page 72
0 to 15 Increments of 500 ms (500 ms to 8 sec)
423
Reserved
0
1
424
System Options 1
Refer to page 73
1 Bosch smart lockout allowed
2 Horn speaker monitor
4 Strobe indication for radio arm/disarm
8 Horn speaker beeps for radio arm/disarm