User Guide56 DCP-300
12 Appendices
Appendix A – Defaults
Default Settings
The table below shows the DCP-300 factory default settings and whether or not user changes to these
settings are retained after a power-cycle (turning the device off and on):
Parameter Factory Default Retained on Power-Down
Program Number
& Voice Selected
0 No
Voice Button Bank Selection Off No
Bank MSB Number 0 No
Bank LSB Number 0 No
Transmit Channel 00 (channel 1) No
Octave shift 0 No
Transpose 0 No
Local On No
Data Control Assignment Data = cc: 007 Volume Yes
Data Control Value
(per assignment and only CC - not
including PGM or Bank LSB/MSB)
Value of cc:007 Yes
Velocity Curve Selected ‘NORMAL’ Yes
Voice Volume 127 Yes
Metronome Volume 127 Yes
Master Tune 0 Yes
Tempo 120 Yes
Reverb On/Off Reverb On Yes - store for each sound
Reverb Depth Defaults for each sound Yes - store for each sound
Reverb Type Defaults for each sound Yes - store for each sound
Chorus On/Off Chorus Off Yes - store for each sound
Chorus Depth Defaults for each sound Yes - store for each sound
Chorus Type Defaults for each sound Yes - store for each sound
Split Mode On/Off Off No
Split Point Eb3 Yes
Split Mode Voice 8 - Upright Bass Yes
Split Volume 127 Yes
Layer Mode On/Off Off No
Layer Mode Voice 7 - Strings Yes
Layer Volume 100 Yes
At power-on, the following MIDI data will be sent to the sound engine, the USB MIDI and the MIDI Out:
1. Bank Change MSB=0, LSB=0, PGM=0 - Set sound engine to piano voice
2. Reverb default value
3. Chorus default value