Sony SRP-X500P Music Mixer User Manual


 
SRP-X500P RS-232C Interface Manual
Return packet format
When the SRP-X500P receives the command successfully, the parameter is returned together with an ACK
(0x41 (‘A’)) in the order shown below.
0x41
parameter” 0x0D
The parameter consists of 8 bytes of data and is the same as that of the OUTPUT FADER command.
2.1.7 REMOTE 1-6 LEVEL : 0x43 0x4C 0x56 0x4C (‘CLVL’)
This command is used to set the level of the REMOTE faders.
The level of the REMOTE faders are reset to 0 dB when the SRP-X500P is turned off.
Packet format
0x43 0x4C 0x56 0x4C parameter” 0x0D
Parameter
The parameter consists of 2 bytes of data in the order shown in the following table.
Byte Parameter
1st Channel
2nd LEVEL
Channel (1st byte)
Specifies the REMOTE fader channel.
The parameter and the REMOTE fader channel are as shown in the following table.
Channel
REMOTE 1 0x42 (‘B’)
REMOTE 2 0x43 (‘C’)
REMOTE 3 0x44 (‘D’)
REMOTE 4 0x45 (‘E’)
REMOTE 5 0x46 (‘F’)
REMOTE 6 0x47 (‘G’)
Page 10/43