SRP-X500P RS-232C Interface Manual
1. Overview
1.1 About This Manual
This manual is the Interface Manual for the Sony SRP-X500P Digital Powered Mixer. The protocol explained in
this manual is designed for controlling the SRP-X500P Digital Powered Mixer from an externally connected
computer. This manual should be used together with the Operating Instructions and the User’s Guide.
Note
The material contained in this manual consists of information that is the property of Sony Corporation and is
intended solely for use by purchasers of the equipment described in this manual.
Sony Corporation prohibits the duplication or use of any portion of this manual without expressed written
permission from Sony Corporation for any purpose other than the operation or maintenance of the equipment
described in this manual.
In this manual, numeric values are indicated as follows:
Unmarked numbers : decimal numbers
Numbers prefaced by “0x” (e.g., 0x10) : hexadecimal numbers
Numbers enclosed by single quotation marks (‘ ’) : ASCII-converted hexadecimal numbers code
1.2 Connecting the SRP-X500P to a Computer
Connect the COM port of the computer to the REMOTE RS-232C connector of the SRP-X500P.
The REMOTE RS-232C connector of the SRP-X500P has the following specifications.
Terminal configuration : D-sub 9-pin, male, inch-sized screws
Electrical specifications : Conforms to the RS-232C standard
Connections :
Pin No. Name
1 NC
2 RXD
3 TXD
4 OPEN
5 GND
6 NC
7 NC
8 NC
9 OPEN
6978
12345
SRP-X500P Computer COM port
REMOTE RS-232C connector (for D-sub 9-pin, male connector)
Name Pin No. Pin No. Name
RXD 2 3 TXD
TXD 3 2 RXD
GND 5 5 GND
Page 3/43