Texas Instruments THS4012 Musical Instrument Amplifier User Manual


 
THS4012 EVM Inverting Operation
1-7
General
1.5 THS4012 EVM Inverting Operation
Although the THS4012 EVM is shipped preconfigured for dual-channel
noninverting operation, it can be reconfigured for inverting operation by
making the following component changes:
1) Move resistor R3 to the R2 location and R5 to the R4 location on the board.
2) Move resistor R11 to the R10 location and R13 to the R12 location on the
board.
This configuration is shown in Figure 1–3. Note that compensation capacitors
C3 and C6 are not installed.
Figure 1–3. THS4012 EVM Schematic — Inverting Operation
C1
6.8 µF
–VCC
1
GND
2
+VCC
3
J2
C2
6.8 µF
–VCC
+VCC
+
U1:A
THS4012
1
4
8
2
3
R4
1 k
R6
1 k
+VCC
C3
x µF
R7
49.9
Vout1
J3
C4
0.1 µF
–VCC
R2
0
J1
Vin1
R1
49.9
+
U1:B
THS4012
7
6
5
R12
1 k
R14
1 k
C6
x µF
R15
49.9
Vout2
J5
R10
0
J4
Vin2
R9
49.9
C5
0.1 µF