U t i l i t y F u n c t i o n s
ECHO BACK
Settings: Off, Thru, RecMontr
Determines whether MIDI data received via the MIDI IN terminal is
simultaneously re-transmited (“echoed back”) via the MIDI OUT
connector. When this parameter is set to “Off” no echo back
occurs. When set to “Thru” the received MIDI data is re-transmitted
without modification. When “RecMontr” (Record Monitor) is se-
lected, the received data is re-transmitted on the MIDI channel
corresponding to the currently selected record track, and the data is
affected by the MIDI FILTER settings described below.
LOCAL CONTROL
Settings: Off, On
Determines whether or not the QY70’s internal tone generator will
be controlled by its own micro-keyboard. When LOCAL CONTROL is
“On”, the micro-keyboard controls the internal tone generator.
When “Off” the micro-keyboard does not control the internal tone
generator and will produce no sound.
MIDI FILTER
Settings: Off, PB, CC, AT, Exc
The MIDI FILTER specifies a type of event which will not be re-
ceived via MIDI during sequence recording. The settings are as
follows:
Off All events are received.
PB Pitch bend events will not be received.
CC Control Change events will not be received.
AT Channel and polyphonic aftertouch events will not be
received.
Exc System exclusive data will not be received.