Ashly WR-5 Music Mixer User Manual


 
Three output expansion cards
added
Complete post-mixer system
processor for all speaker locations
Electrical box mounted remote
DC level controller for Dressing
Rooms
Three input expansion
cards added
Four independent room
systems can easily be
reconfigured using contact
closure preset recall
Electrical box mounted
remote DC level controller for
each room
Use Remote Level Control
input to mute channels during
emergency
Fire alarm drives relay when
active. Relay connects
ne24.24M 0-5V Remote Level
Control Ground to desired pin,
muting all channels assigned in
software (see sec. 10.1)
Mixing
Console
Output
1
2
3
4
Inputs
1-3
4-6
7-9
10
11
12
Outputs
L
C
R
Subs
Under Balcony
(Delay)
Lobby
13-14
LCR Inputs:
- Ducked Signal
Mic Input:
- Ducking Input
LCR Outputs:
- HPF / LPF
- Alignment Delay
- EQ
- Limiter
Dressing Room
- Wall Mount
Remote Level
Control
Left / Center / Right
Theater System
L
C
R
Dressing Room
Paging Mic
15-16
Dressing
Room 3&4
Dressing
Room 1&2
HF
MF
LF
HF
MF
LF
HF
MF
LF
Remote
Control
1
Inputs
Outputs
Conference Center
System
AV Input
2
3
4
Meeting Room 1
Room Divider
1
Ceiling Speakers
Room Volume Control
5
AV Input
6
7
8
Meeting Room 2
2
Ceiling Speakers
Room Volume Control
9
AV Input
10
11
Ballroom 1
Room Divider
3
Main Speakers
Room Volume Control
Ballroom 2
4
Main Speakers
Room Volume Control
Portable Mixer Output
12
13
AV Input
14
15
Portable Mixer Output
16
Contact Closure
Preset Panel for
Room Combining
ASHLY AUDIO INC. 847 Holt Road Webster, NY 14580
Phone: (585) 872-0010 Fax: (585) 872-0739
Toll Free (800) 828-6308 www.ashly.com © 2008Ashly Audio Corporation R0
Fire Alarm Mute
Configuration
Emergency Alarm System
Connector on
ne24.24M
Back Panel
Alarm Relay
Drive Output
Relay (shown alarm off)
Switched Ground
To Desired Pin for
Mute All Function