Appendices ~ Appendix E: Serial Commands
47
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
AD
This command changes the state of the auto disconnect function.
[DEVICE] AD <X>
Explanation
<X>
X=0 Parameter to set Auto Disconnect to OFF
X=1 Parameter to set Auto Disconnect to LOOP
X=2 Parameter to set Auto Disconnect to Call
Progress (CP)
X=3 Parameter to set Auto Disconnect to LOOP+CP
X=Null Parameter to report back the current state
Return Values
The command will return the updated connection state of the unit
in the same format as the command. If the sent command changes
the state of the unit, the updated state is returned.
If: Command returns:
current disconnect state is OFF [DEVICE] AD 0
current disconnect state is LOOP [DEVICE] AD 1
current disconnect state is CP [DEVICE] AD 2
current discon. state is LOOP+CP [DEVICE] AD 3
AGC
This command changes or reports back the state of the AGC
for a microphone or line input.
[DEVICE] AGC <CH> <X>
Explanation
<CH>
CH= 1-4 Parameter to apply to the
specified microphone channel
CH= A-D Parameter to apply to the
specified line input
CH= * Parameter to apply command
to all microphone channels
<X>
X=0 Parameter to set the state to OFF
X=1 Parameter to set the state to ON
X=2 Parameter to toggle the state from one
state to the other (regardless of current
state)
X=Null Parameter to return the current state
Return Values
The command will return the updated condition (On=1,
Off=0) of the AGC in the same format as the command.