ClearOne comm AP400 Musical Instrument User Manual


 
Appendices ~ Appendix E: Serial Commands
57
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
MMAX
This command changes or reports back the setting for the
maximum number of microphones on each AP400.
[DEVICE] MMAX <X>
Explanation
<X>
X=0 Parameter to set the maximum to no limit
X=1-8 Parameter to set the maximum number of
microphones allowed on
X=Null Parameter to return the maximum number
of microphones allowed on
Return Values
The command will return the updated maximum number of
microphones allowed on for the selected AP400 in the same format
as the command.
MPASS
This command sets the current password for modem mode. Note:
The default password is a carriage return (enter). If the password
is forgotten, it can be cleared back to a carriage return via the
front panel.
[DEVICE] MPASS <STRING>
Explanation
STRING can be any character combination up to 8 characters. If
STRING is not specified the command returns the currently
assigned string. To specify no initialization string, set STRING to
CLEAR.
Return Values
Once the command is given, the unit responds by echoing back the
command.
MTRX
This command programs or reports the configuration of a
routed input. The data is in a hex format. See the matrix
configuration table for specific routing information.
[DEVICE] MTRX <INPUT> <OUTPUTMIX>
Explanation
<INPUT>
Input=1-25 selects the input to be routed to the mix
outputs.
Input Input word assignment
1 Mic input 1 post gate
2 Mic input 2 post gate
3 Mic input 3 post gate
4 Mic input 4 post gate
5 Reserved
6 Reserved
7 Reserved
8 Reserved
9 Line input A
10 Line input B
11 Line input C
12 Line input D
13 Subbus 1
14 Reserved
15 G-Link X
16 G-Link Y
17 G-Link Z
18 Mic input 1 pregate
19 Mic input 2 pregate
20 Mic input 3 pregate
21 Mic input 4 pregate
22 Telco input pregate
23 Reserved
24 Reserved