ClearOne comm AP400 Musical Instrument User Manual


 
Appendices ~ Appendix E: Serial Commands
63
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
PP
This command changes or reports back the state of the phantom
power for a microphone.
[DEVICE] PP <CH> <X>
Explanation
<CH>
CH= 1-4 Parameter to apply to the specified
microphone channel
CH= * Parameter to apply command to all microphone
channels
<X>
X=0 Parameter to set the state to OFF
X=1 Parameter to set the state to ON
X=Null Parameter to return the current state
Return Values
The command will return the updated condition (On=1, Off=0) of
the phantom power in the same format as the command.
PRESET
This command selects or reports the current preset configuration
used by the AP400.
[DEVICE] PRESET <X>
Explanation
<X>
X=1-6 Sets the preset to the number specified
X=Null Parameter to return the current preset
Return Values
The command will return the current preset. If the command
changed the preset, the updated preset is returned.
REFSEL
This command selects or returns the output to be used as the
EC Reference and PA (speaker output).
[DEVICE] REFSEL <X> <OUTPUT>
Explanation
<X>
X=1 Parameter to select the EC
Reference and PA (speaker
output)
X=2 Parameter to select the G-Link
EC Ref bus
<OUTPUT>
OUTPUT=1-4 Parameter to select 1-4 as the
EC reference and PA (speaker
output)
OUTPUT=A-D Parameter to select A-D as the
EC reference and PA (speaker
output)
OUTPUT=E Parameter to select G-Link EC
Ref bus as the EC Reference and
PA (speaker output)
OUTPUT=F Parameter to select none
OUTPUT=Null Parameter to return the EC
reference and PA (speaker
output) value
Return Values
The command will return the updated condition of the
reference and PA (speaker output) select in the same format
as the command.