ClearOne comm PSR1212 Musical Instrument User Manual


 
122
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Appendices ~ Appendix E: Serial Commands
SIGTOUT - Signal Generator Time Out
Sets the signal generator time out for the unit.
Command form: DEVICE
SIGTOUT
[Value]
Argument details
Name Description
Device 0–7 or * to select all units
SIGGEN Command
Value 0 = Off, 1–30 = Set time out minutes, Null = Current rate
Example:
#47 SIGTOUT 15
On PSR1212 unit 7 (
#47
), the signal generator
time out (
SIGTOUT
) is set to
15
minutes.
STRING - String Execution
This command sends the specified string out the serial port.
Command form: DEVICE
STRING
[ID]
Argument details
Name Description
Device 0–7 or * to select all units
STRING Command
ID 0 – 7
Null to query last string in text
Example:
#41 STRING 3
On PSR1212 unit 1 (
#41
), the
STRING
programmed
into location
3
will be sent out the RS-232 port.
TOUT - Time Out Select
This command selects/reports the inactivity time out before returning to the unit title
screen.
Command form: DEVICE
TOUT
[Value]
Argument details
Name Description
Device 0–7 or * to select all units
TOUT Command
Value 0 = Off, 1–15 (select time out in minutes)
Null = Current mode
Example:
#42 TOUT 5
On PSR1212 unit 2 (
#42
), the front panel of the unit
will time out (
TOUT
) after
5
minutes.
The serial command to
create a string is
PRGSTRING (Program
String). See page 118.
-