Installation ~ LCD Programming
Menu items can still be
scrolled through when
the panel is locked.
However, settings cannot be
entered until the panel is
unlocked with the appropriate
passcode.
-
To unlock the front panel, attempt to adjust a parameter. The PSR1212 will
prompt for the passcode. Upon entering the fifth character (if entered correctly),
the front panel will unlock. The default passcode for all boxes is ssttEnter.
Set Passcode
Once the PSR1212 is unlocked, the passcode can be changed. Before the PSR1212
will allow passcode changes, the new passcode must be entered, then re-entered to
validate the new passcode.
The front panel passcode can also be set (and reset) within G-Ware. See page
26 for more information.
Device ID
The PSR1212’s device ID is set from this menu. There are eight device ID selections
to choose from (0–7). Select the network position you want to use. Within a single
site, you must assign different device ID numbers for each PSR1212 unit. See Device
IDs, page 12.
Unit ID
The Unit ID menu selection allows you to access the read-only address set at the
factory. This unique ID number identifies your particular PSR1212 unit and cannot
be changed.
Mixer Mode
This setting allows you to set to master or slave mode. See page 12 for details.
Firmware Version
This menu selection allows you to view which firmware version is being used. This
information cannot be changed.
RS-232 menu
There are four submenus under the RS-232 menu: Baud Rate, Flow Control, Enable
Modem, and Clear Password.
Baud Rate
This parameter allows you to set the PSR1212’s baud rate to 9.6kbps, 19.2kbps,
38.4kbps, or 57.6kbps. Default is 38.4kbps. Select the baud rate you want to use,
then press Enter.