2. Congure the MLC 104 IP Plus.
a. Using Global Congurator, congure the MLC’s
Digital I/O port for digital input with pull-up.
b. Configure a monitor to send an e-mail when the
Digital I/O port closes.
N
RefertotheGlobalConguratorhelplefor
MLC configuration instructions.
3. Test the instant alert notication.
a. Ensure that the MLC 104 IP Plus is connected to the
network.
b. Press and hold the two Volume buttons on the
microphone simultaneously for 2 seconds. The
receiver’s LED blinks alternating amber and green.
N
Make sure that the microphone is on either
channelAorchannelB.
c. Check for the arrival of the e-mail notification.
Ç
Configure the MLC’s Digital I/O port for
digital input with pull-up.
Ö
Press and hold both Volume buttons
for 2 seconds.
Press and hold both
volume buttons
simultaneously.
2-17