Extron electronic VLM 1000 Microphone User Manual


 
2-21
VoiceLift Microphone Installation • Reference Information
Specications — VLC 102 Microphone Charging Station
General
External power supply ................. 110 VAC to 130 VAC, 50/60 Hz, external, 2 prong; to 5 VDC, 1 A, regulated
3.5 mm o.d. jack, center positive
Power input requirements ........... 5 VDC, 0.5 A
Temperature/humidity ................ Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing
Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing
Cooling ........................................... Convection, no vents
Mounting ........................................ Set on desktop
Enclosure type ............................... High impact plastic
Enclosure dimensions ................... 1.8" H x 4.1" W x 3.0" D
(4.6 cm H x 10.4 cm W x 7.6 cm D)
Product weight .............................. 0.3 lbs (0.1 kg)
Shipping weight ............................ 1 lb (1 kg)
Vibration ......................................... ISTA 1A in carton (International Safe Transit Association)
Regulatory compliance
EMI/EMC .......................... FCC Class B
Environmental ................... Complies with the appropriate requirements of ENERGY STAR
®
(ENERGY
STAR qualied power supply, efciency level IV), RoHS, and WEEE.
MTBF ............................................... 30,000 hours
Warranty ......................................... 3 years parts and labor
N
Specicationsaresubjecttochangewithoutnotice.