5 - 73
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
Setting Value, setting range
Value set with peripheral device
Setting value buffer memory
address
Servo amplifier setting invalid
(
: Valid, : Invalid)
MR-J3-B
Value set with PLC program
Default
value
Axis 1 Axis 2 Axis 3 Axis 4
1 to 10000 337 30128 30328 30528 30728
0 to 1000 980 30129 30329 30529 30729
100 to 4500 4500 30131 30331 30531 30731
0
1: is used to set up the setting
value.
(Hexadecimal)
Notch depth selection
Notch width selection
H
0
0000
H
30132 30332 30532 30732
100 to 4500 4500 30133 30333 30533 30733
2: The PB
corresponds with servo parameter No. of the servo amplifier.
3: Set the parameter value and switch power off once (The parameter is transferred to servo amplifier from QD75MH), then switch it
on again to make that parameter setting valid.