5 - 160
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
Setting item Setting details
Cd.19
OPR request flag OFF
request
•
The PLC program can use this data item to forcibly turn the OPR request flag
from ON to OFF.
POINT
This parameter is made valid when the increment system is valid.
Cd.20
Manual pulse generator 1
pulse input magnification
•
This data item determines the factor by which the number of pulses from the
manual pulse generator is magnified.
•
Value "0" : read as "1".
•
Value "1001" or less: read as "1000".
Cd.21
Manual pulse generator
enable flag
•
This data item enables or disables operations using a manual pulse generator.
Cd.22
New torque value
•
When changing the "
Md.35
Torque limit stored value", use this data item to
specify a new torque limit stored value.
•
Set a value within the allowable range of the "
Pr.17
Torque limit setting value".