15 TROUBLESHOOTING
Related buffer memory
address
Axis 1 Axis 2 Axis 3 Axis 4
Set range
(Setting with PLC program)
Remedy
74
75
224
225
374
375
524
525
<OPR speed>
1 to 50000000 [PLS/s]
1 to 2000000000 [mm/min or others]
• Set the value inside the setting range.
• Set the speed to the bias speed at start or higher.
(Refer to Section 5.2.5)
76
77
226
227
376
377
526
527
<Creep speed>
1 to 50000000 [PLS/s]
1 to 2000000000 [mm/min or others]
• Set the value inside the setting range.
• Set the speed to that below the home position return
(OPR) speed.
• Set the value to the bias speed at start or higher.
(Refer to Section 5.2.5)
78 228 378 528 0, 1
79 229 379 529 0 to 65535
80
81
230
231
380
381
530
531
0 to 2147483647
82 232 382 532 0, 1, 2, 3
83 233 383 533 0, 1, 2, 3
After setting the value inside the setting range, turn the
PLC READY signal [Y0] from OFF to ON.