Pelco C586M Electronic Keyboard User Manual


 
18 Pelco Manual C586M (9/99)
1. Follow the steps under “Run a sequence of cameras
from one multiplexer on the MAIN monitor” or “Run a
sequence of cameras from one multiplexer on the
SPOT monitor” to start sequencing the cameras on the
main and spot monitors of individual multiplexers that
you want to sequence.
2. Hold down the SEQ key for approximately three
seconds to start sequencing the multiplexers.
1. Press the
key.
2. Press the SEQ key.
Move the joystick or select any camera.
Program the monitor in the Advanced System Setup
menu.
1. Press the MAIN or SPOT MONITOR key. The green
LED over the MAIN or SPOT key lights. When using the
MAIN MONITOR, the SPOT MONITOR DISPLAY menu
item in the Advanced System Setup menu must be
set to TRACK MAIN (refer to the
Advanced System
Setup
section).
2. Select the camera.
Addressing by Multiplexer (Switch 7 OFF)
a. On the number pad, press the address number of the
multiplexer (1-16 if the keyboard is connected to a
multiplexer; 1-8 if the keyboard is connected to a
server), then press the UNIT key. The LED displays
the address.
b. On the number keypad press the number of the
camera (1-16), then press the CAM key.
Addressing Consecutively (Switch 7 ON)
On the number keypad press the number of the
camera, then press the CAM key. Refer to Table D for
camera numbers.
3. On the number keypad press the number of the preset,
then press the PRESET key. (Note: When calling preset
95 on Esprit or Spectra systems, hold the PRESET key
until the menu appears on the screen.)
Table C. Operation Guide (Continued)
Starts sequencing the multiplexers
in numerical order, displaying the
main monitor first, then the spot
monitor. Monitors to be displayed
are selected in the Set Sequence
submenu of the Monitor menu of
the server. As each monitor is
displayed, it sequences. Sequenc-
ing appears on the monitor
affiliated with the keyboard; for
example, if the keyboard is set for
address 1, the sequence will
appear on monitor 1.
Sequences all active cameras in
the PIP display.
OPERATION KEYBOARD COMMAND RESULT
(Continued on next page)
Stop a sequence of
multiplexers.
Call a camera or run a
sequence of cameras
on the AUX monitor
(duplex multiplexer
only).
Sequence multiplexers
connected to a server
and sequence cameras
on a multiplexer(s).
Sequence the PIP
display.
Sequence stops.
Monitor responds to programming
instructions.
Call a preset.
Moves the camera to the preset
location.