Sanyo DSR-3000 Recording Equipment User Manual


 
RECORDING IMAGES IN THE
ALARM RECORDING AREA
Alarm recording
1 Setting the time
Press the MENU button to display the LANGUAGE/CLOCK SET menu, and set
the date and time. After the setting has been made, press the EXIT/OSD button,
the date and time appear in the operating display. (See page 42.)
2 Set alarm recording.
Press the MENU button to display the ALARM REC MODE SET menu from
the MAIN MENU screen. Then change the ALARM RECORDING setting to
the desired alarm recording setting (MODE1, 2, 3 or 4) and change the
ALARM TRIGGER setting. (See page 54 ~ 56.)
Press the MENU button, to display the BUZZER SET menu from the MAIN
MENU 2 screen, and change the ALARM setting to ON. (See page 62.)
Press the EXIT/OSD button to return to the normal screen.
Suspicious person detection
When an alarm occurs, ALARM appears in the operating display, the ALARM
indicator flashes and alarm recording (a symbol) starts. Alarm images are
recorded in the alarm recording area. Furthermore, the number of alarms in the
operating display is increased by one each time an alarm occurs.
Note: Normal recording and timer recording stop when an alarm occurs during
normal recording or timer recording.
Ending alarm recording
Recording ends after the end of the alarm duration period (default setting: 1 sec).
The “a and ALARM displays stop flashing and recording stops.
Note: When the remaining area in the alarm recording area reaches 1%, the
ALARM FULL indicator on the front panel flashes. If recording is continued
under these conditions, the recording area is filled and the recording
stops. In the RECORDING AREA SET settings, carry out the AREA FULL
RESET operation for the alarm recording area.
Overwriting will be canceled and recording will be possible from the
beginning again. (See page 48.)
MENU
1
<MAIN MENU 1>
1.LANGUAGE/CLOCK SET ->
2.VIDEO INPUT SET ->
3.RECORDING AREA SET ->
4.RECORDING CONDITIONS SET ->
<LANGUAGE/LANGUE/IDIOMA>
ENGLISH
<CLOCK SET>
01-01-2001 MON 00:00:00
SS
<ALARM REC MODE SET>
PICTURE QUALITY : ENHANCED
FRAME/FIELD RECORDING : FIELD
AUDIO RECORDING : OFF
ALARM RECORDING : MODE1
REC CYCLE : 0.10SEC. DURATION: 1SEC
PRE-ALARM RECORDING : ¤¤¤
REC CYCLE : ¤¤¤ SEC. DURATION: ¤¤¤
=> (46400 ALARMS CAN BE RECORDED)
ALARM TRIGGER : ALARM
MOTION SENSOR ->
ALARM
2
10-05-01 ALARM 0001
18:10:25 EN 0.10SEC
The number of
alarms is counted.
3
POWER FULL
ALARM FULL
LOC
Alarm images are
recorded
English
17