Cisco Systems RPS 675 Recording Equipment User Manual


 
CHAPTER
3-1
Cisco RPS 675 Redundant Power System Hardware Installation Guide
78-15201-03
3
Troubleshooting
The Cisco Redundant Power System (RPS) 675 is not repairable in the field.
Table 3-1 shows the appropriate action to take for specific LED indications.
Table 3-1 LED Indications and Appropriate Action
Symptom Condition Action
Standby/Active
LED is blinking
amber.
The RPS is in standby
mode.
Press the Standby/Active button to
put the RPS in active mode.
Standby/Active
LED is off.
The AC power
connection to one or
both of the internal
power supplies is
faulty or not
connected.
Check the AC power connection to
external power.
If the AC power is connected
properly, the problem might be with
the RPS internal power supplies.
Output Power
LED is amber.
The DC output power
from the internal
power supplies is not
available or is not
functioning correctly.
An internal power supply is
defective, or the RPS has reacted to
an overcurrent condition. Press the
Standby/Active button. If the LED
color does not turn green, replace the
RPS 675.
Temperature
LED is amber.
The RPS 675 is
approaching an
overtemperature
condition.
Reduce the ambient temperature.