Cisco Systems RPS 675 Recording Equipment User Manual


 
A-1
Cisco RPS 675 Redundant Power System Hardware Installation Guide
78-15201-04
APPENDIX
A
Technical Specifications
Table A-1 lists the technical specifications for the Cisco Redundant Power System
(RPS) 675 (model PWR675-AC-RPS-N1=). Table A-2 lists the agency approvals.
Table A-1 Technical Specifications for the RPS 675
Environmental Ranges
Operating temperature 32 to 113°F (0 to 45°C)
Storage temperature –4 to 149°F (–20 to 65°C)
Operating humidity 10 to 85% (noncondensing)
Storage humidity 5 to 95% (noncondensing)
Operating altitude Up to 10,000 ft (3,000 m)
Storage altitude Up to 15,000 ft (4,570 m)
Power Requirements
AC input voltage 100 to 240 VAC (autoranging)
6 to 10 A, 50 to 60 Hz
875 W
Power delivery (available
power)
Total
375 W per –48 VDC output and
300 W per 12 VDC output
Standby power
1
25 W