Roland VGA-7 Musical Instrument Amplifier User Manual


 
44
Operating the VGA-7 with the FC-200
Functions That Can Be
Controlled with the FC-200
In Program Change Mode
fig.95
Switching Between Preset Patches and
User Patches
* Distinctions between Preset and User Patches follow the
VGA-7 settings.
Switching Banks
Each time the Bank (UP/DOWN) pedal is pressed, the bank
is switched, and the Bank is indicated on the FC-200s
display.
Press UP to rise through the bank numbers in sequence;
press DOWN to descend through the sequence of Bank
numbers.
Switching Numbers
Press the Number pedals (110) to select the numbers. The
selected number indicator lights, and the program number is
switched.
When switching to a Patch of a different number within the
same Bank, reselection of the Bank is unnecessary.
When in Control Change mode, you can use the UP bank
pedal to switch between Preset and User Patches.
Turning the Tuner On and Off
Each time the control pedal is pressed, the information
controlled with the pedal is sent from the FC-200 as a Control
Change message (Controller Number 80).
These messages can be used to turn the VGA-7s tuner on
and off.
Controlling the Volume (Wah)
When the expression pedal is used, the information
controlled with the pedal is sent from the FC-200 as a Control
Change message (Controller Number 7).
These messages can be used to control the VGA-7s volume
level.
When EFX in the EFFECTS section is on, with the TYPE set to
WAH, you can use the expression pedal as a wah pedal.
In Control Change Mode
In Control Change mode, the various pedals are used to send
the Control Change messages shown below.
These messages can be used to control the VGA-7s different
functions.
fig.97
Switching Preset and User Patches
Each time the UP Bank pedal is pressed, the information
controlled with the pedal is sent from the FC-200 as a Control
Change message (Controller Number 75).
These messages can be used to switch between Preset and
User Patches.
Turning the Capo Function On and Off
Each time Number pedal 6 is pressed, the information
controlled with the pedal is sent from the FC-200 as a Control
Change message (Controller Number 70).
These messages can be used to turn the Capo function on and
off.
Switching BanksSwitching Numbers
Turning the Tuner On and Off
Controlling the
Volume (Wah)
Turning the Capo Function
On and Off (#70)
Switching Preset and
User Patches (#75)
Turning the EFX On and Off (#65)
Turning the Delay On and Off (#66)
Turning the Chorus On and Off (#67)
Turning the Reverb On and Off (#68)
Delay Time Tap Input (#69);
When HOLD is selected as the Delay type,
this is used to start and stop recording.
Switching Between
Manual and Memory (#76)
Controlling the
Volume (Wah) (#7)
Turning the
Tuner On and Off (#80)