Sony SRP-X700P DJ Equipment User Manual


 
29
Before contacting a Sony Sales office or Dealer, check the following again. If the trouble persists, contact
your local Sony Sales office or Dealer.
Troubleshooting
Cause/Remedy
USB cable is not connected.
Check the connection of the USB cable.
The dedicated USB driver software is not installed.
Install the dedicated USB driver software. (Refer to page 4.)
Index is not set.
Set up the index using SRP-X700P Manager. (Refer to pages 8, 26, and 27.)
FADER select is set to INACTIVE mode.
Set the FADER select to ACTIVE mode. (Refer to pages 10 and 15.)
The SRP-X700P is not connected.
Check the connection of the SRP-X700P.
There is an error in the GROUP FADER screen setup.
Check the GROUP FADER screen setup. (Refer to page 26.)
Muting is on.
Cancel muting. (Refer to pages 9, 14, and 26.)
FRONT PANEL LOCK button remains in the ON position.
Set the FRONT PANEL LOCK button to the OFF position. (Refer to page 7.)
An attempt is made to increase the sound volume exceeding the OVER GAIN setup value.
Decrease the fader. (Refer to pages 10 and 15.)
Set up the GAIN LIMIT again. (Refer to pages 10 and 14.)
FADER is set in the
position.
Increase the FADER. (Refer to pages 10 and 15.)
Muting is on.
Cancel muting. (Refer to pages 9, 14, and 26.)
Temperature of the heat sink inside the amplifier exceeds the specified value.
Turn off the main power and remove the cause of the temperature rise.
Impedance of the speaker connected is too low.
Turn off the main power and connect the SRP-X700P to another speaker having the
proper impedance.
The speaker terminals are short-circuited.
Turn off the main power and remove the cause of the short-circuit.
The Power-On Setting is set to DEFAULT or SCENE No. 1.
Set the Power-On Setting to LAST MEMORY. Alternatively, store the parameter in
SCENE No. 1 when the Power-On Setting is set to SCENE No. 1. (Refer to page 27.)
The setup file that is saved by the SRP-X700P Manager version 1.1 is going to be opened
by the SRP-X700P Manager version 1.0.
Uninstall the SRP-X700P Manager version 1.0 and install the SRP-X700P Manager
version 1.1. (Refer to page 5.)
The computer in which the SRP-X700P Manager version 1.0 is installed, is going to be
connected to the SRP-X700P version 1.1.
Uninstall the SRP-X700P Manager version 1.0 and install the SRP-X700P Manager
version 1.1. (Refer to page 5.)
Symptom
Cannot operate the system from User
Control Panel.
Cannot operate the system using
SRP-X700P Manager.
Index is not displayed when using
User Control Panel.
Cannot operate FADER by remote
control.
Cannot control the sound volume.
OVER GAIN indicator remains lit.
Cannot increase the sound volume
more than a certain level.
No sound comes out.
PROTECTION indicator is lit.
Setup parameters change when power
is turned off.
When setup file is opened, the error
message Invalid property value
appears on the REMOTE screen.
The error message Unable to
connect to SRP-X700P. Please be
sure of connection of USB cable and
power status of apparatus appears,
and communication with the SRP-
X700P cannot be established.