47
9.4.1. Parametric equalizer
[OUT1] FILTER1
TYPE PE
Q
PARAMETER
PUSH-ENTER
CHANGE
• Rotate the Setting knob to select PEQ and enter the Parametric
Equalizer setting screen.
• Pressing an Output channel selector key permits the filter to be
set for that channel. The [OUT 1] indication changes to the
selected channel number indication.
• The setting screen reverts to the Input/Output Gain Setting
screen when the shift key is pressed.
[Gain settings]
[OUT1] FILTER1
GAIN +0.0d
B
PARAMETER
PUSH-ENTER
CHANGE
• Rotate the Setting knob to set the gain.
Parameter setting range: –15 to +15 dB in 0.1 dB steps
• Pressing an Output channel selector key permits the filter to be
set for that channel. The [OUT 1] indication changes to the
selected channel number indication.
[Center frequency settings]
[OUT1] FILTER1
FREQ 1.00kH
z
PARAMETER
PUSH-ENTER
CHANGE
• Rotate the Setting knob to set the center frequency.
Parameter setting range: 20 Hz – 20 kHz in 1/24 octave steps
• Pressing an Output channel selector key permits the filter to be
set for that channel. The [OUT 1] indication changes to the
selected channel number indication.
[Q settings]
[OUT1] FILTER1
Q 0.26
7
PARAMETER
PUSH-ENTER
CHANGE
• Rotate the Setting knob to set the Q.
Parameter setting range: 0.267 – 69.249 (96 points)
• Pressing an Output channel selector key permits the filter to be
set for that channel. The [OUT 1] indication changes to the
selected channel number indication.
9.4.2. High-pass filter
[OUT1] FILTER1
TYPE HPF - 6d
B
PARAMETER
PUSH-ENTER
CHANGE
• Rotate the Setting knob to select either HPF-6 dB or HPF-12 dB
and enter the High-Pass Filter setting screen.
The indications of 6 dB and 12 dB represent the slope: 6 dB/oct
and 12 dB/oct, respectively.
• Pressing an Output channel selector key permits the filter to be
set for that channel. The [OUT 1] indication changes to the
selected channel number indication.
• The setting screen reverts to the Input/Output Gain Setting
screen when the shift key is pressed.
[Cutoff frequency settings]
[OUT1] FILTER1
FREQ 1.00kH
z
PARAMETER
PUSH-ENTER
CHANGE
• Rotate the Setting knob to set the cutoff frequency.
Parameter setting range: 20 Hz – 20 kHz in 1/24 octave steps
• Pressing an Output channel selector key permits the filter to be
set for that channel. The [OUT 1] indication changes to the
selected channel number indication.