Agilent Technologies E2251A Drums User Manual


 
32
E2273A 8-Channel Form C Switch Wiring Information
User
Connector
Pins
User
Connector
Pins
CH0 NC
CH0 NO
CH0 com
CH1 NC
CH1 NO
CH1 com
CH4 NC
CH4 NO
CH4 com
CH5 NC
CH5 NO
CH5 com
CH2 NC
CH2 NO
CH2 com
CH3 NC
CH3 NO
CH3 com
CH6 NC
CH6 NO
CH6 com
CH7 NC
CH7 NO
CH7 com
Channel 0
Channel 1
Channel 3
Channel 4
Channel 5
Channel 2
Channel 6
Channel 7
29
30
28
25
26
24
21
22
20
17
18
16
1
3
2
14
15
13
10
11
9
6
7
5
NC = Normally Closed
NO = Normally Open
com = Common
CGND: Pin 4, 8, 12, 19, 23, 31 - 44
MAXIMUM VOLTAGE/CURRENT: The maximum voltage
that may be applied to any connector on the E2273A is
200 VDC, 141 VAC rms, or 200 VAC peak. These limits
apply only if the product is installed in a humidity-con-
trolled (<60% RH) environment where airborne contami-
nants and transients are controlled, and there is NOT a
relay connection made to power mains. If these condi-
tions CANNOT be maintained, then the maximum volt-
age is 60 VDC, 48 VAC rms or 68 VAC peak.
The maximum current (non-inductive) that may be
applied to the E2273A is 1 ADC, 1 AACpeak per switch.
Maximum power is 40W DC, 40VA AC per switch; 100W
DC, 100VA AC per M-Module.