AMX NXC-M/ME/MPE Drums User Manual


 
Product Information - NetLinx Modules
1
NetLinx Master Cards and Modules
Product Information - NetLinx Modules
NetLinx Master Cards and Modules are the controllers for NetLinx Control Systems. The Master
Cards can be installed in the NetLinx CardFrame (NXF), the NetLinx Integrated Controller (NXI),
or a NetLinx Module (NXS-MHS) for stand-alone operation.
The NetLinx Master Cards/Modules covered in this document are:
NXM-MHS (NXM Modules)
NXM-MHS Modules accomodate one NetLinx Master (or Hub) Card. Master Cards can also be
installed in an NXI (NetLinx Integrated Controller), or NXF (NetLinx CardFrame).
FIG. 1 shows the front panel of an NXM module. The front panels are always the same; the rear
panel components are different depending on the features of the Master Card installed.
NXM-MHS specifications
The rear panel components described here are common to all Master Cards/Modules. Components
that are specific to a particular Master Card/Module are described in the Specifications section for
that card.
NXM-MHS NetLinx Master/Hub Module
NXC-M Master Card
NXC-ME Master-Ethernet Card
NXC-MPE Master Port Expander Card
FIG. 1 NXM-MHS (front)
NXM-MHS Specifications
Front Panel Components:
Program port DB-9 (male) connector that supports RS-232 communications to your PC
for system programming and diagnostics. You set the port's communica-
tion speed with the Baud Rate DIP switch. See the Program Port DIP
switch - baud rate settings section on page 2 for details.
There are Program ports located on the front and rear panels of the Mas-
ter Cards for easy access. Because these ports share the same circuitry,
you should never use both ports at the same time. Doing so will result in
communication and/or programming errors.
Status LED Green LED blinks to indicate that the system is programmed and commu-
nicating properly.
Output LED Red LED blinks when the Master Card transmits data, sets channels on
and off, sends data strings, etc.
STATUS OUTPUT INPUT
MASTER