AMX NXC-M/ME/MPE Drums User Manual


 
Product Information - NetLinx Modules
3
NetLinx Master Cards and Modules
DIP switch positions 3 and 4 are reserved for future features and should always be set to the Off
(down) position.
Program Port DIP switch - Program Run Disable (PRD) mode
You can also use the Program Port DIP switch to set the Master Card to Program Run Disable
(PRD) mode according to the settings listed in the table below:
PRD mode prevents the NetLinx program stored in the Master Card from running when you power
up the Master Card. PRD mode should only be used when you suspect the resident NetLinx
program is causing inadvertent communication and/or control problems. If necessary, place the
Master Card in PRD mode and use the NetLinx Studio program to resolve the communication and/
or control problems with the resident NetLinx program. Then, download the new NetLinx program
and try again.
Setting the Program Port DIP Switch
1. Disconnect the power supply from the 2-pin PWR (green) connector on the Master Card.
2. Remove the front faceplate and mounting screws (four) from the Master Card's front panel.
Then, locate the Program Port DIP switch (to the left of the Program port).
3. Set DIP switch positions according to the information listed in the Baud Rate Settings and
PRD Mode Settings tables above.
4. Replace the front panel and faceplate back onto the Master Card and reconnect the 12 VDC
power supply to the 2-pin PWR connector.
Baud Rate Settings
Baud Rate Position 5 Position 6 Position 7 Position 8
9600 bps OFF ON OFF ON
38,400 bps (default) OFF ON ON ON
57,600 bps ON OFF OFF OFF
115,200 bps ON ON ON ON
PRD Mode Settings
PRD Mode Position 1 Position 2
Normal mode (default) OFF OFF
PRD Mode ON OFF